![]() |
Andy Evans is Brain DEAD
"Andy Evans is Brain DEAD "
I have some projects with 300b SET amps built on two chassis - power supply and signal chassis. Right now I'm using amphenol 4 pin AP series connectors for earth and HT - which is about 440v or 490vDC off load. I'm wondering about a simpler coax option, since I really only need HT and earth (rest can be done with 4/5 pin XLRs and 4/8 pin speakons). The umbilical can be fixed at the PSU end and detachable at the signal chassis. So a female socket on the cable and a male one on the chassis. ** Using an RF co-ax connector for this job is totally insane !!!! None of the readily available types are even vaguely safe as they allow finger contact with the core terminal. No readily available connector is entirely safe for delivering high voltage DC and earth to an exposed chassis. There is far too much risk that due to damage, normal wear and tear or partial insertion of the line plug in the socket a situation arises where the DC power ground ( ie chassis earth ) is NOT connected while the high voltage DC is. This event will render the amp chassis live and lethal - a person would be CRIMINALLY liable for leaving such a set up lying around. The same rules apply as with any mains powered appliance that requires a safety earth - particularly that the safety earth conductor MUST NOT also be a current carrying conductor. Speakon ( and PowerCon ) connectors have the unfortunate characteristic that the back cover unscrews in the fingers and exposes internal live parts - makes them quite unsafe for use as domestic mains power or high voltage connectors. And it is illegal to use them in that way. The Speakon connector twists to actually connect the contacts - making it very possible for a partial twist to connect the high voltage DC contacts but not connect the ground contacts. The only suggestion I have is to stick with the Amphenol 4 pin AP connector and use 3 out of the 4 pins to carry the ground connection back to the PSU. Make sure the cable has 4 wires in it for complete, 3 wire redundancy. Shame the Evans congenital retard is not gonna take one blind bit of notice of any of this. ...... Phil |
My parrot thinks it's a Boeing 707
Although so far I've only been able to get 60 people on board it.
|
Moonlight becomes you
On Oct 4, 2:38 pm, "Phil Allison" wrote:
"Andy Evans is Brain DEAD " I have some projects with 300b SET amps built on two chassis - power supply and signal chassis. Right now I'm using amphenol 4 pin AP series connectors for earth and HT - which is about 440v or 490vDC off load. I'm wondering about a simpler coax option, since I really only need HT and earth (rest can be done with 4/5 pin XLRs and 4/8 pin speakons). The umbilical can be fixed at the PSU end and detachable at the signal chassis. So a female socket on the cable and a male one on the chassis. ** Using an RF co-ax connector for this job is totally insane !!!! None of the readily available types are even vaguely safe as they allow finger contact with the core terminal. No readily available connector is entirely safe for delivering high voltage DC and earth to an exposed chassis. There is far too much risk that due to damage, normal wear and tear or partial insertion of the line plug in the socket a situation arises where the DC power ground ( ie chassis earth ) is NOT connected while the high voltage DC is. This event will render the amp chassis live and lethal - a person would be CRIMINALLY liable for leaving such a set up lying around. The same rules apply as with any mains powered appliance that requires a safety earth - particularly that the safety earth conductor MUST NOT also be a current carrying conductor. Speakon ( and PowerCon ) connectors have the unfortunate characteristic that the back cover unscrews in the fingers and exposes internal live parts - makes them quite unsafe for use as domestic mains power or high voltage connectors. And it is illegal to use them in that way. The Speakon connector twists to actually connect the contacts - making it very possible for a partial twist to connect the high voltage DC contacts but not connect the ground contacts. The only suggestion I have is to stick with the Amphenol 4 pin AP connector and use 3 out of the 4 pins to carry the ground connection back to the PSU. Make sure the cable has 4 wires in it for complete, 3 wire redundancy. Shame the Evans congenital retard is not gonna take one blind bit of notice of any of this. ..... Phil |
My parrot thinks it's a Boeing 707
"Andy Evans = mental retard" Although so far I've only been able to get 60 people on board it. ** Evans is a classic example of an autistic mental retard. It even builds crappy and dangerous SET amps to prove the fact. Wot a PITA, ****ing puke. ...... Phil |
My parrot thinks it's a Boeing 707
That is because you forgot to take into account the placebo effect I
imagine. Brian -- Brian Gaff - Note:- In order to reduce spam, any email without 'Brian Gaff' in the display name may be lost. Blind user, so no pictures please! "Andy Evans" wrote in message ... Although so far I've only been able to get 60 people on board it. |
All times are GMT. The time now is 10:20 AM. |
Powered by vBulletin® Version 3.6.4
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
SEO by vBSEO 3.0.0
Copyright ©2004-2006 AudioBanter.co.uk