One for the valvies 2/2....
Fleetie wrote:
"Wally" wrote
Keith G wrote:
OK, exactly why don't trannies (on valve amps) like it being run
without a load?
I think it has something to do with the xformer's secondary trying to drive
a very large impedance (ie, open circuit). I think this translates into
excessive current in the primary (but I could be wrong).
I'd have thought quite the reverse; usually, I'd have thought the
primary current would decrease when the load was removed from the
secondary.
Yes, it will, without the reflected load the primary reverts to
effectivly choke loaded. But the secondary is still a inductor, and so
does what comes naturally to it.
Think about how ignition coils in cars work, its the rapid di/dt that
causes a high voltage.
Mind you, if there's feedback and so on happening round it all, goodness
only knows.
Its not a feedback issue, just inductors at play.
--
Nick
|