"Eiron" wrote in message
...
I rescued a Rotel RA930AX amp from the junk shop.
The manual says:
"Do not use speakers that have a very high capacitive load,
say over 0.1 microfarads, as it may cause a damage to the
power amplifier section."
So I shan't be connecting it to my ESLs.
Any idea what would happen?
**Actually, you're likely to experience fewer problems with the Rotel, than
with most other amps. I am a Rotel service agent and part of the testing
procedure I use on ALL amps (except Naim of course) is to connect a 1uF cap
across the load, to check for instability issues. Rotels do not exhibit
problems.
--
Trevor Wilson
www.rageaudio.com.au