View Single Post
  #4 (permalink)  
Old December 2nd 07, 02:18 PM posted to rec.audio.tubes,uk.rec.audio
Don Pearce
external usenet poster
 
Posts: 1,822
Default Plate characteristics at low anode currents

On Sun, 02 Dec 2007 15:07:54 +0000, Ian Thompson-Bell
wrote:

Don Pearce wrote:
On Sun, 02 Dec 2007 13:51:44 +0000, Ian Thompson-Bell
wrote:

I have being playing around with plate characteristics graphs, looking
at how basic parameters (gm,rp and mu) vary with operating point. The
most frustrating thing about this is that the published curves all
extend to rather large plate currents and voltages. For my preamp I am
working at plate currents of less than 5mA and the curves here are
rather cramped. Is there any source of curves that are expanded for the
lower plate current region?

Cheers

Ian


It's a long, boring Sunday afternoon. Perfect time to do a set of
measurements like this and post the results somewhere. If this is an
area of valve performance that is poorly documented it would be
interesting to know what kind of variation there is between samples.

d



Been there, done that, wrote the spreadsheet.

Some months ago I ran 32 different 6AU6 tubes in triode mode and
measured gm, rp and mu at an Ia of 3.8mA and Vp of 100V. I have the
results in a spreadsheet if you are interested.

Wouldn't mind a look if you can put it somewhere convenient, although
from interest only, as it is unlikely I will do any design work with
it.

I don't really want to repeat that work every time I decide to use a
different tube. What I don't understand is why the manufacturers data
extends so far away from normal operating points such that the data at
the operating point is of poor resolution - but I guess most them aren't
around to ask. The best data for the 6AU6 in triode mode I have lists Ia
up to over 30mA and Vb to over 400V. OK so you load line is likely to
hit the Ia axis at twice your quiescent, but if that is say 5mA and Vb
is 250V then you are trying to read info off the graph in the bottom
left hand eighth of the graph.

Have you tried using log axes? They might make things more usable over
a wider range.

d
--
Pearce Consulting
http://www.pearce.uk.com