View Single Post
  #16 (permalink)  
Old July 10th 08, 01:11 PM posted to uk.rec.audio
Eeyore
external usenet poster
 
Posts: 1,415
Default earth loop problem



Eiron wrote:

Don Pearce wrote:

Doesn't matter. You only connect to earth for safety.


That's not quite true. You sometimes connect to earth to eliminate hum.
I had a setup that wasn't earthed and when someone approached the microphone
it hummed; when they touched a chassis point it stopped humming.
That wasn't an earth loop but it was capacitative pickup of mains
interference as the ground of all the double-insulated kit was
floating at a hundred volts or so.


A (design ?) defect.


Modern laptop PSUs have three core mains leads


Nonsense.

so it probably doesn't happen on new kit.


Equally nonsense. The Y cap bridging the live and secondary sides is still there
(for EMC - LOL).

Graham