Thread
:
interference sources
View Single Post
#
4
(
permalink
)
April 27th 09, 06:42 PM posted to uk.rec.audio
Brian Gaff
external usenet poster
Posts: 637
interference sources
That was what I meant, its audible on medium wave, but the direction nulling
only seems to locate it in our block not much else. I've had all my stuff
out, and the neighbour one way seems clear, but its just like you might
hear from an AC arc, but in a short say up to ten seconds burst, then thirty
seconds of nothing, then its back again, and its very loud on medium, even
worse on long wave and detectable on the fm band as well.
Brian
--
Brian Gaff -
Note:- In order to reduce spam, any email without 'Brian Gaff'
in the display name may be lost.
Blind user, so no pictures please!
"Don Pearce" wrote in message
news:49f5768a.924662281@localhost...
On Mon, 27 Apr 2009 09:08:48 GMT, "Brian Gaff"
wrote:
Hi folks, just in the last two weeks I've had some resets of a freeview
box,
and decided to listen around the bands to see if it was being caused by
some odd mains borne stuff. It seems it is.
The offending signal is easily detected 24 hours as a kind of arcing noise
every 30 seconds or so. My thoughts are maybe..
Charger trying to see if it needs to charge, plug in air freshener, or
something else. I've tried to locate it with a portable radio as the
signal
on medium wave is horrendously loud even on a portable.
Results are inconclusive. Not being on the best of terms with the property
implicated here, I am trying to find some way to approach them and
knowing
if there is some device like this might be one of the ways. I'm thinking
along the lines of it might be going to catch fire or similar.
I'd have thought if it is affecting me, its affecting them.
Brian
When you describe the sound, do you mean it is something you can hear
without using a radio? If so it should be easy enough to find.
If not, the medium wave radio can be used as a direction finder
(assuming it uses a ferrite rod antenna). Orient it until the
interference is at a minimum - the rod will then be pointing directly
at the source.
Sounds like the problem could be something like a thermostat, although
the size of the signal makes it sound like the load is inductive
rather than resistive. Whatever, it is quite likely that the problem
will go away soon because I am betting that switch is well on its way
to total failure.
d
Brian Gaff
View Public Profile
View message headers
Find all posts by Brian Gaff
Find all threads started by Brian Gaff