Advice on a power supply umbilical needed.
I have some projects with 300b SET amps built on two chassis - power
supply and signal chassis. Right now I'm using amphenol 4 pin AP series connectors for earth and HT - which is about 440v or 490vDC off load. I'm wondering about a simpler coax option, since I really only need HT and earth (rest can be done with 4/5 pin XLRs and 4/8 pin speakons). The umbilical can be fixed at the PSU end and detachable at the signal chassis. So a female socket on the cable and a male one on the chassis. I have no experience of coax connectors - there's the cheap and plentiful BNC, the more robust N type, then TNC, UHF etc etc. The connector must be comfortable at 500v, but the other requirement would be that the cable connector - presumably female - should be sufficiently shrouded that it's very hard to touch since there's over 400vDC on it!! Best choice here? andy |
Advice on a power supply umbilical needed.
"Andy Evans" wrote in message
... Best choice here? Err. stay with what you've got? Why do you want to change? and why do you think co-ax appropriate for DC? And if you are using 5-pin XLRs for "the rest" why not use them for this as well? Your whole approach seems arbitrary and illogical. David. |
Advice on a power supply umbilical needed.
In article
, Andy Evans wrote: I have some projects with 300b SET amps built on two chassis - power supply and signal chassis. Right now I'm using amphenol 4 pin AP series connectors for earth and HT - which is about 440v or 490vDC off load. I'm wondering about a simpler coax option, since I really only need HT and earth (rest can be done with 4/5 pin XLRs and 4/8 pin speakons). The umbilical can be fixed at the PSU end and detachable at the signal chassis. So a female socket on the cable and a male one on the chassis. I have no experience of coax connectors - there's the cheap and plentiful BNC, the more robust N type, then TNC, UHF etc etc. The connector must be comfortable at 500v, but the other requirement would be that the cable connector - presumably female - should be sufficiently shrouded that it's very hard to touch since there's over 400vDC on it!! Best choice here? If you want posh go for Lemo. They make co-ax connectors suitable for high power transmitters where I'd guess there are a fair few volts flying around. But be prepared to dig deep... -- *A bicycle can't stand alone because it's two tyred.* Dave Plowman London SW To e-mail, change noise into sound. |
Advice on a power supply umbilical needed.
"Andy Evans has no Brain" I have some projects with 300b SET amps built on two chassis - power supply and signal chassis. Right now I'm using amphenol 4 pin AP series connectors for earth and HT - which is about 440v or 490vDC off load. I'm wondering about a simpler coax option, since I really only need HT and earth (rest can be done with 4/5 pin XLRs and 4/8 pin speakons). The umbilical can be fixed at the PSU end and detachable at the signal chassis. So a female socket on the cable and a male one on the chassis. ** Using an RF co-ax connector for this job is totally insane !!!! None of the readily available types are even vaguely safe as they allow finger contact with the core terminal. No readily available connector is entirely safe for delivering high voltage DC and earth to an exposed chassis. There is far too much risk that due to damage, normal wear and tear or partial insertion of the line plug in the socket a situation arises where the DC power ground ( ie chassis earth ) is NOT connected while the high voltage DC is. This event will render the amp chassis live and lethal. The same rules apply as with any mains powered appliance that requires a safety earth - particularly that the safety earth conductor MUST NOT also be a current carrying conductor. Speakon ( and PowerCon ) connectors have the unfortunate characteristic that the back cover unscrews in the fingers and exposes internal live arts - makes them quite unsafe for use as domestic mains power or high voltage connectors. The Speakon twists to actually connect the contacts - making it very possible for a partial twist to connect the high voltage DC contacts but not connect the ground contacts. The only suggestion I have is to stick with the Amphenol 4 pin AP connector and use 3 out of the 4 pins to carry the ground conection back to the PSU. Make sure the cable has 4 wires in it for complete redundancy. ...... Phil |
Advice on a power supply umbilical needed.
On Sat, 3 Oct 2009 15:15:28 -0700 (PDT), Andy Evans
wrote: I have some projects with 300b SET amps built on two chassis - power supply and signal chassis. Right now I'm using amphenol 4 pin AP series connectors for earth and HT - which is about 440v or 490vDC off load. I'm wondering about a simpler coax option, since I really only need HT and earth (rest can be done with 4/5 pin XLRs and 4/8 pin speakons). The umbilical can be fixed at the PSU end and detachable at the signal chassis. So a female socket on the cable and a male one on the chassis. I have no experience of coax connectors - there's the cheap and plentiful BNC, the more robust N type, then TNC, UHF etc etc. The connector must be comfortable at 500v, but the other requirement would be that the cable connector - presumably female - should be sufficiently shrouded that it's very hard to touch since there's over 400vDC on it!! Best choice here? andy Have a look here, you should find something safe that will fit the bill. Not cheap though, I'm guessing. http://www.ges-electronic.com/connector/multipin_hv.php d |
Advice on a power supply umbilical needed.
In article , Dave Plowman (News)
wrote: In article , Andy Evans wrote: I have no experience of coax connectors - there's the cheap and plentiful BNC, the more robust N type, then TNC, UHF etc etc. The connector must be comfortable at 500v, but the other requirement would be that the cable connector - presumably female - should be sufficiently shrouded that it's very hard to touch since there's over 400vDC on it!! Best choice here? If you want posh go for Lemo. They make co-ax connectors suitable for high power transmitters where I'd guess there are a fair few volts flying around. But be prepared to dig deep... I'd agree with the above since IIRC Lemo make designs specifically for high voltage uses, and they can provide self-locking. That, combined with being totally incompatable with the usual audio plugs would help avoid accidents. You will, of course, have to also choose a cable that is designed for high DC voltages. Lemo do tend to be expensive - but cheap if they save your life. Slainte, Jim -- Please use the address on the audiomisc page if you wish to email me. Electronics http://www.st-and.ac.uk/~www_pa/Scot...o/electron.htm Armstrong Audio http://www.audiomisc.co.uk/Armstrong/armstrong.html Audio Misc http://www.audiomisc.co.uk/index.html |
Advice on a power supply umbilical needed.
Hello again,
Thanks for the contributions. I'll answer the questions first! David Looser - nothing is either arbitrary or illogical here. The connectors are chosen for the following criteria: 1) They are cheap and widely available. So Don and Dave - yes, plenty of Lemo and Amphenol to drool over! You have my sympathies here! But I arrived at Amphenol AP because it was a much cheaper option for the voltage required, while being available from most suppliers. 2) They carry voltages within their voltage rating. Here, David, note that XLRs are now rated as 50v. They were rated at 300v or so but have been re-rated in conformity with newer regulations, so XLRs are now not an option for high voltages. So they are used for filament voltages. Speakons are rated 300v. They could no doubt carry more but I'm using an Amphenol AP connector because it's rated 660v. 3) They are not confused with other connectors. So 3 pin XLRs are out for power supplies, 4 and 5 pin are possible. Speakons could theoretically be an issue but they are only used on the power supply where they are fixed to the chassis. There's no power on the signal chassis end so you couldn't connect a speaker to it unless the amp had no power to it. 4) They are safe in use - fingers can't touch live parts. Speakons are nice here because shrouded, but they don't have the voltage rating for 490v. Yes the backs unscrew, though when you screw them up tight they are pretty hard to unscrew. A theoretical hazard maybe, but well noted. Thanks for pointing that out, Phil. So having arrived at the current solution by careful logic, it's a good question "why change it"! I don't have to - it works perfectly well. The amphenol connectors are nice and easy to use, though a little large. The advantages of a coax connector is that I could buy already made up leads, which would save time. Now this is where Phil is very informative - thanks Phil! None of the readily available types are even vaguely safe as they allow finger contact with the core terminal. This was indeed my question. I haven't handled these connectors so I'm only going by photos - you can't handle a photo so I don't know what can and can't be touched. So you reckon - as above - that all these coax connectors could be touched? That would rule them out really if that's the case. So again Phil says stick with the Amphenol. Earth and HT connect simultaneously, earth is a nice big size. Cable is rated for 1,000v. Of the 4 connections two are for HT and earth, and one is for fixed bias if used, so typically -30v or something. So I do have one connection available. So what is the suggestion of carrying the ground connection back to the PSU? How is this implemented and what's the advantage? andy |
Advice on a power supply umbilical needed.
"Andy Evans is Totally Brain Dead " I'm using an Amphenol AP connector because it's rated 660v. ** Fraid the maker says the connector is only *safe* for 50 volts. http://www.amphenolaudio.com/catalog.../page77_78.pdf See note 1. Christ alive - the Evan pommy puke is one PIG ARROGANT MORON !!! ...... Phil |
Advice on a power supply umbilical needed.
"Phil Allison" wrote in message
... "Andy Evans is Totally Brain Dead " I'm using an Amphenol AP connector because it's rated 660v. ** Fraid the maker says the connector is only *safe* for 50 volts. http://www.amphenolaudio.com/catalog.../page77_78.pdf It says: "Not suitable for domestic applications above 50V". This is because it is possible to touch the female contacts with a bit of wire or something, which is the sort of thing an unsupervised child might do. If there is no possibility of the uncoupled connector being accessed when powered is applied, then this restriction does not apply. David. |
Advice on a power supply umbilical needed.
On Sun, 4 Oct 2009 01:23:01 -0700 (PDT), Andy Evans
wrote: Hello again, Thanks for the contributions. I'll answer the questions first! David Looser - nothing is either arbitrary or illogical here. The connectors are chosen for the following criteria: 1) They are cheap and widely available. So Don and Dave - yes, plenty of Lemo and Amphenol to drool over! You have my sympathies here! But I arrived at Amphenol AP because it was a much cheaper option for the voltage required, while being available from most suppliers. 2) They carry voltages within their voltage rating. Here, David, note that XLRs are now rated as 50v. They were rated at 300v or so but have been re-rated in conformity with newer regulations, so XLRs are now not an option for high voltages. So they are used for filament voltages. Speakons are rated 300v. They could no doubt carry more but I'm using an Amphenol AP connector because it's rated 660v. 3) They are not confused with other connectors. So 3 pin XLRs are out for power supplies, 4 and 5 pin are possible. Speakons could theoretically be an issue but they are only used on the power supply where they are fixed to the chassis. There's no power on the signal chassis end so you couldn't connect a speaker to it unless the amp had no power to it. 4) They are safe in use - fingers can't touch live parts. Speakons are nice here because shrouded, but they don't have the voltage rating for 490v. Yes the backs unscrew, though when you screw them up tight they are pretty hard to unscrew. A theoretical hazard maybe, but well noted. Thanks for pointing that out, Phil. So having arrived at the current solution by careful logic, it's a good question "why change it"! I don't have to - it works perfectly well. The amphenol connectors are nice and easy to use, though a little large. The advantages of a coax connector is that I could buy already made up leads, which would save time. Now this is where Phil is very informative - thanks Phil! None of the readily available types are even vaguely safe as they allow finger contact with the core terminal. This was indeed my question. I haven't handled these connectors so I'm only going by photos - you can't handle a photo so I don't know what can and can't be touched. So you reckon - as above - that all these coax connectors could be touched? That would rule them out really if that's the case. So again Phil says stick with the Amphenol. Earth and HT connect simultaneously, earth is a nice big size. Cable is rated for 1,000v. Of the 4 connections two are for HT and earth, and one is for fixed bias if used, so typically -30v or something. So I do have one connection available. So what is the suggestion of carrying the ground connection back to the PSU? How is this implemented and what's the advantage? andy You can use that one spare connection for ground, but is that something different from the one you already nominate as Earth? Not too clear about that. d |